alternative to using an uninterruptible power supply, and a second level of fault tolerance when used in conjunction with an uninterruptible power supply.
The temperature of the TR 700 Battery is generally
Attention: It is recommended that you replace the TR 700 Battery annually or after 500 recharging cycles, whichever comes first.
Installing the TR 700 Battery
Attention: Do not open your server or attempt any repair before reading and understanding “Safety information” on page iii and “Guidelines” on page 69.
This topic provides instructions on how to install the TR 700 Battery on a ThinkServer RAID 700 Adapter if your server has one installed.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another computer for reference.
Note: Use any documentation that comes with the TR 700 Battery and follow those instructions in addition to the instructions in this topic.
To install the TR 700 Battery, do the following:
1.Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server.
2.If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat, clean, and
3.Remove the server cover. See “Removing the server cover” on page 71.
4.Remove the cooling shroud. See “Removing and reinstalling the cooling shroud” on page 76.
5.Remove the riser card assembly 1 and lay it upside down on a flat, clean, and
6.Remove the ThinkServer RAID 700 Adapter, which is a kind of RAID card, from the riser card assembly 1. See “Replacing the RAID card” on page 140.
Note: Carefully handle the ThinkServer RAID 700 Adapter by its edges and place it on a flat, clean, and
7.Touch the