Diagnostic Error Code

FRU/Action

 

 

 

006-197-XXX

1.

If a component is called out, make sure

Diskette interface test warning

 

it is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

006-198-XXX

1.

If a component is called out, make sure

Diskette interface test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 111

 

3.

Go to “Undetermined problems” on page

 

 

78

 

 

 

006-199-XXX

1.

Go to “Undetermined problems” on page

Diskette interface test failed, cause unknown

 

78

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

006-25X-XXX

1.

Diskette drive cable

Diskette interface Error

2.

Diskette drive

 

 

3.

System board

 

 

011-000-XXX

No action

Serial port Interface Test Passed

 

 

 

 

 

011-001-XXX

1.

Remove external serial device, if

Serial port Presence

 

present

 

 

 

2.

Run setup, enable port

 

3.

System board

 

 

011-002-XXX

System board

011-003-XXX

 

 

Serial port Timeout/Parity error

 

 

 

 

011-013-XXX

System board

011-014-XXX

 

 

Serial port Control Signal/Loopback test

 

 

failure

 

 

 

 

 

011-015-XXX

1.

Wrap plug

Serial port External Loopback failure

2.

System board

 

 

 

 

011-027-XXX

1.

Run Setup, enable port

Serial port Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 111

 

3.

System board

 

 

011-03X-XXX

System board

011-04X-XXX

 

 

Serial port failure

 

 

 

 

011-195-XXX

Information only

Serial port Test aborted by user

Re-start the test, if necessary

 

 

 

011-196-XXX

1.

Press F3 to review the log file

Serial port test halt, error threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

60Lenovo E200 Hardware Maintenance Manual

Page 66
Image 66