Lenovo E200 manual XXX If a component is called out, make sure, 011-199-XXX, XXX No action

Models: E200

1 124
Download 124 pages 28.92 Kb
Page 67
Image 67

Diagnostic Error Code

FRU/Action

 

 

 

011-197-XXX

1.

Make sure the component that is called

Serial port test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2. Re-run test

 

3. Replace the component that is called out

 

 

in warning statement

 

4. Replace the component under test

 

 

 

011-198-XXX

1.

If a component is called out, make sure

Serial port test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2. Flash the system and re-test. See “Flash

 

 

update procedures” on page 111

 

3. Go to “Undetermined problems” on page

 

 

78

 

 

 

011-199-XXX

1.

Go to “Undetermined problems” on page

Serial port test failed, cause unknown

 

78

 

 

 

2. Flash the system and re-test. See “Flash

 

 

update procedures” on page 111

 

3. Replace component under function test

 

 

 

011-2XX-XXX

1.

External serial device

Serial port signal failure

2.

System board

 

 

 

014-000-XXX

No action

Parallel port Interface Test Passed

 

 

 

 

 

014-001-XXX

1.

Remove external parallel device, if

Parallel port Presence

 

present

 

 

 

2. Run setup, enable port

 

3.

System board

 

 

014-002-XXX

System board

014-003-XXX

 

 

Parallel port Timeout/Parity error

 

 

 

 

014-013-XXX

System board

014-014-XXX

 

 

Parallel port Control Signal/Loopback test

 

 

failure

 

 

 

 

 

014-015-XXX

1.

Wrap plug

Parallel port External Loopback failure

2.

System board

 

 

 

 

014-027-XXX

1.

Run Setup, enable port

Parallel port Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 111

 

3.

System board

 

 

014-03X-XXX

System board

014-04X-XXX

 

 

Parallel port failure

 

 

 

 

014-195-XXX

Information only

Parallel port Test aborted by user

Re-start the test, if necessary

 

 

 

Chapter 7. Symptom-to-FRU Index 61

Page 67
Image 67