Lenovo E200 manual 025-199-XXX, XXX No action, 030-00X-XXX Scsi signal cable 030-01X-XXX

Models: E200

1 124
Download 124 pages 28.92 Kb
Page 72
Image 72

Diagnostic Error Code

FRU/Action

 

 

 

025-198-XXX

1.

If a component is called out, make sure

IDE interface test aborted

 

it is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 111

 

3.

Go to “Undetermined problems” on page

 

 

78

 

 

 

025-199-XXX

1.

Go to “Undetermined problems” on page

IDE interface test failed, cause unknown

 

78

 

 

 

2.

Flash the system and re-test. See “Flash

 

 

update procedures” on page 111

 

3.

Replace component under function test

 

 

030-000-XXX

No action

SCSI interface Test Passed

 

 

 

 

 

030-00X-XXX

1.

SCSI signal cable

030-01X-XXX

2.

Check power supply

SCSI interface failure

3.

SCSI device

 

 

4.

SCSI adapter card, if installed

 

5.

System board

 

 

 

030-027-XXX

1.

SCSI signal cable

SCSI interface Configuration/Setup error

2.

Flash the system. See “Flash update

 

 

 

procedures” on page 111

 

3.

SCSI device

 

4.

SCSI adapter card, if installed

 

5.

System board

 

 

 

030-03X-XXX

1.

SCSI signal cable

030-04X-XXX

2.

Check power supply

SCSI interface error

3.

SCSI device

 

 

4.

SCSI adapter card, if installed

 

5.

System board

 

 

030-195-XXX

Information only

SCSI interface Test aborted by user

Re-start the test, if necessary

 

 

 

030-196-XXX

1.

Press F3 to review the log file

SCSI interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

030-197-XXX

1.

Make sure the component that is called

SCSI interface test warning

 

out is connected and/or enabled. See

 

 

 

 

Chapter 6, “Using the Setup Utility,” on

 

 

page 49

 

2.

Re-run test

 

3.

Replace the component that is called out

 

 

in warning statement

 

4.

Replace the component under test

 

 

 

66Lenovo E200 Hardware Maintenance Manual