TECHNICAL SPECIFICATIONS – WELD-PAK 100

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

Input Current

 

 

 

 

115V/60Hz

20 Amps - Rated Output

115V/60Hz

15 Amps - CSA Rated output

 

 

 

 

RATED OUTPUT

 

 

 

Duty Cycle

Amps

Volts at Rated Amperes

 

 

 

 

 

 

 

 

 

 

20% Duty Cycle

88

 

 

18

 

 

20% Duty Cycle – CSA Rated Output

62

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

Welding Current Range (Continuous) Maximum Open Circuit Voltage

Auxiliary Power

 

Rated DC Output: 0 - 88 amps

 

32

 

 

 

N/A

 

 

CSA Rated DC Output: 0 - 62 amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Mode

Input Voltage

Fuse or

Input Amps

Power Cord

 

 

Extension Cord

 

 

Breaker Size

 

 

 

RATED

115V/60Hz

20 Amp

20

15 Amp, 125V,

 

 

Three Conductor

 

 

 

#14 AWG

 

 

 

 

 

 

 

Three Prong Plug

 

 

 

 

 

 

 

 

 

 

 

(2.1 mm2) or Larger

 

 

 

 

 

 

 

(NEMA Type 5-15P)

 

 

 

 

 

 

 

 

 

Up to 25 Ft. (7.6 mm)

 

 

 

 

 

 

 

 

 

 

 

CSA

115V/60Hz

15 Amp

12

15 Amp, 125V,

 

 

Three Conductor

 

 

 

 

 

 

 

Three Prong Plug

 

 

#12 AWG

 

 

 

 

 

 

 

(NEMA Type 5-15P)

 

(3.3 mm2) or Larger

 

 

 

 

 

 

 

 

 

 

Up to 50 Ft. (15.2 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

Height

Width

Depth

 

Weight

 

 

12.0 in

 

9.75 in

16.5 in

 

47 Ibs

 

 

305 mm

248 mm

419 mm

 

21.4 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 