TROUBLESHOOTING & REPAIR

F-4

 

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

No weld output - auxiliary power

1. Check the open circuit voltage

1.

Check continuity (zero ohms) of

 

(230 - 115 VAC) operates normally

(OCV) at the welder output ter-

 

lead W1A (black) from output

 

- engine runs normally.

minals. If OCV is okay, go to

 

terminal to reactor (L1). See the

 

 

Step 2, below.

 

Wiring Diagram.

 

 

 

 

If OCV is not present at the welder

2.

Check continuity (zero ohms) of

 

 

output terminals, contact your

 

lead W2 (black) from output ter-

 

 

local Lincoln Electric Authorized

 

minal to stator winding. See the

 

 

Field Service Facility.

 

Wiring Diagram.

 

 

 

 

2. Check the welding cables,

3.

Check continuity (zero ohms) of

 

 

clamps and electrode holder for

 

lead W1 (black) from reactor

 

 

loose or broken connections.

 

(L1) to stator winding. See the

 

 

 

 

Wiring Diagram.

 

 

 

 

 

4.

Check reactor (L1) for continuity

 

 

 

 

of winding. See the Wiring Dia-

 

 

 

 

gram.

 

 

 

 

 

5.

Check the stator for continuity

 

 

 

 

of winding. See the Wiring Dia-

 

 

 

 

gram.

 

 

 

 

 

6.

Make certain the reactor and/or

 

 

 

 

stator are NOT grounded. Mini-

 

 

 

 

mum acceptable resistance to

 

 

 

 

ground is 500 K-ohms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.