Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-34

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

 

No Load RPM

Load RPM

Maximum Speed

3725

3650

Minimum Speed

3675

3400

WELDER/GENERATOR OUTPUT1

Output Control

Field Volts

Field Amps

Open Circuit

Load Volts

Load Amps

 

 

 

 

Volts

 

 

 

 

Maximum

43 - 49

4.8 - 5.8

60 - 63

12 - 25

120

- 125

 

Minimum

55 - 60

14 - 27

75

- 85

 

 

 

 

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

115 Volt Receptacle2

Output

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Control

Volts

 

 

Volts

 

 

Maximum

255 - 267

215 - 230

18 - 20

127 - 133

112 - 120

18 - 20

 

 

 

 

 

 

 

1Current Control Dial set at MAXIMUM or GENERATOR.

2Output values of each receptacle can vary within the range shown

12/95 POWER-ARC 4000

Page 75
Image 75
Lincoln Electric SVM103-A Retest After Repair, Engine Output, WELDER/GENERATOR OUTPUT1, Auxiliary Power Receptacle OUTPUT1