TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR
Retest a machine:
•If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
| No Load RPM | Load RPM |
Maximum Speed | 3725 | 3650 |
Minimum Speed | 3675 | 3400 |
WELDER/GENERATOR OUTPUT1
Output Control | Field Volts | Field Amps | Open Circuit | Load Volts | Load Amps |
| |
|
|
| Volts |
|
|
|
|
Maximum | 43 - 49 | 4.8 - 5.8 | 60 - 63 | 12 - 25 | 120 | - 125 |
|
Minimum | – | – | 55 - 60 | 14 - 27 | 75 | - 85 |
|
|
|
|
|
|
|
|
|
AUXILIARY POWER RECEPTACLE OUTPUT1
| 230 Volt Receptacle |
| 115 Volt Receptacle2 | |||
Output | Open Circuit | Load Volts | Load Amps | Open Circuit | Load Volts | Load Amps |
Control | Volts |
|
| Volts |
|
|
Maximum | 255 - 267 | 215 - 230 | 18 - 20 | 127 - 133 | 112 - 120 | 18 - 20 |
|
|
|
|
|
|
|
1Current Control Dial set at MAXIMUM or GENERATOR.
2Output values of each receptacle can vary within the range shown