Lincoln Electric SVM146-A service manual Capacitor Voltage Test, Test Procedure

Models: SVM146-A

1 110
Download 110 pages 45.11 Kb
Page 58
Image 58

to Section TOC

to Master TOC

F-18

F-18

TROUBLESHOOTING & REPAIR

PRIMARY POWER BOARD RESISTANCE TEST AND

CAPACITOR VOLTAGE TEST (continued)

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

CAPACITOR VOLTAGE TEST

This test will help the technician to determine if the input filter capacitors are being charged equally to the correct voltage levels.

NOTE: This test should only be conducted with the PRO-CUT 80 connected for 400 VAC or above, and with the appropriate input voltage applied.

TEST PROCEDURE

1.Remove main input power to the PRO-CUT 80.

2.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

3.Locate and familiarize yourself with the capacitor test locations on the primary power board. See Figure F.3.

4.The following tests will be performed with the input power applied to the PRO-CUT 80. BE CAREFUL. ALWAYS REMOVE

THE INPUT POWER AND PERFORM THE INPUT FILTER CAPACITOR DISCHARGE PROCEDURE BEFORE TOUCHING ANY MACHINE COMPONENT.

WARNING

ELECTRIC SHOCK can kill.

• Have an electrician install and service this equipment.

Turn the input power off at the fuse box before working on equipment.

Do not touch electrically hot parts.

5.Apply the correct input powerand turn ON the PRO-CUT 80.

NOTE: This test should only be conducted with the PRO-CUT 80 reconnect switch and “A” jumper configured for 400 VAC and above.

Return to Section TOC

Return to Master TOC

PRO-CUT 80

Page 58
Image 58
Lincoln Electric SVM146-A service manual Capacitor Voltage Test, Test Procedure