TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

The air begins to flow when the

1.

Make sure the air pressure is

1. Perform the Torch Continuity

 

torch trigger is pulled. There is a

 

set at 70 psi (448 kPa.)

and Solenoid Test.

 

very brief pilot arc. (Normal is 3

2.

Make sure the torch consum-

2. The output board may be faulty.

 

seconds.) The sequence is repeat-

 

 

ables are in place and in good

Replace.

 

ed with subsequent trigger pulls.

 

 

 

condition.

 

 

 

 

 

3. The control board may be

 

 

 

 

 

 

3.

Make sure the air flow is not

faulty. Replace.

 

 

 

restricted.

 

 

 

 

 

 

 

 

The cutting arc starts but sputters

1.

Make sure the operating proce-

1. Perform the Torch Continuity

 

badly.

 

dure is correct for the process.

and Solenoid Test.

 

 

 

See the Operation section of

2. The output board may be faulty.

 

 

 

this manual.

 

 

 

Replace.

 

 

 

 

 

 

2.

Make sure the work clamp is

3. The control board may be

 

 

 

connected tightly to the work-

 

 

 

faulty. Replace.

 

 

 

piece.

 

 

 

 

 

 

 

3.

Make sure the torch consum-

 

 

 

 

 

ables are in place and in good

 

 

 

 

 

condition.

 

 

 

 

4.

Make sure the air supply is not

 

 

 

 

 

contaminated with oil or exces-

 

 

 

 

 

sive water.

 

 

 

 

5.

Make sure the air pressure is

 

 

 

 

 

set at 70 psi (448 kPa.)

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

PRO-CUT 80

Page 46