Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
|
| THEORY OF OPERATION |
|
| ||||
|
|
|
|
|
| |||
|
|
| FIGURE E.2 – INPUT LINE VOLTAGE |
|
|
| ||
|
|
|
|
|
|
|
| WORK |
|
|
|
|
|
|
|
| NOZZLE |
|
|
| POWER BOARD |
|
|
| ELECTRODE |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| MAIN |
|
| TORCH |
|
|
| CR 1&2 |
| OUTPUT | BOARD | CONNECTOR | |
|
|
|
| TRANSFORMER | ||||
|
|
| RELAY |
|
|
|
|
|
|
|
|
|
|
|
|
| E |
INPUT |
|
| IGBT |
|
|
|
| L |
LINE | INPUT |
|
|
|
|
| E | |
|
|
|
|
|
| C | ||
SWITCH | RECTIFIER |
|
|
|
|
|
| T |
|
|
|
|
|
|
|
| R |
|
|
| CAPACITOR |
|
|
|
| O |
|
|
|
|
|
|
| D | |
|
|
|
|
|
|
|
| E |
|
| R |
|
|
|
| CHOKE | S |
|
| E | IGBT |
|
|
| PILOT | O |
|
| C |
|
| TRANSISTOR | L | ||
|
| O |
|
|
|
|
| E |
|
|
|
|
|
|
| N | |
|
| N |
|
|
|
|
| |
|
|
|
|
|
|
| O | |
|
| N |
|
|
|
|
| |
|
|
|
|
|
|
| I | |
|
| E |
|
|
|
|
| |
|
|
|
|
|
|
| D | |
|
| C | IGBT |
|
|
|
| |
|
| T |
|
|
|
|
| |
|
|
| CURRENT |
|
|
|
| |
|
|
|
|
|
|
|
| |
|
| S |
| TRANSFORMER |
|
| TRIGGER & SAFETY | |
|
|
|
|
|
| |||
|
| W |
|
|
|
|
|
|
|
| I | CAPACITOR |
|
|
|
| AIR |
|
| T |
|
|
|
| ||
|
| C |
|
|
|
|
| SOLENOID |
|
| H |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
| IGBT |
|
|
|
|
|
| AIR | P |
|
| TRIGGER & SAFETY |
|
|
|
| R |
|
|
|
|
|
| |
| PRESSURE | O |
|
|
|
|
| REMOTE |
| SWITCH | T | CR 1& 2 | IGBT |
|
|
| |
| "A" | E | RELAY |
|
|
| INTERFACE | |
|
| C | DRIVE | GATE |
|
|
| RECEPTACLE |
|
| T | SIGNALS |
|
|
|
| |
|
| SIGNAL | ELECTRODE & TRANSFER |
|
|
| ||
| L | I |
|
|
|
| ||
| O |
|
| CURRENT FEEDBACK |
|
|
| |
| E | N | SIGNAL |
|
|
|
|
|
|
|
| PILOT ENABLE |
|
|
| ||
|
|
|
|
|
|
|
| |
| A |
|
| CONTROL BOARD | ELECTRODE SOLENOID ENABLE |
|
|
|
|
|
|
|
|
|
| ||
| D |
|
|
|
|
|
| |
|
| 18/36VAC |
| AIR SOLENOID ENABLE |
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| R | A | T | S |
| E | I | H | A |
| R | E | F | |
THERMOSTATS | A | |||
| L | R | E | |
| D | M | T | |
| ||||
| Y | O | A | Y |
|
| W | L |
|
OUTPUT
CONTROL
DISPLAY BOARD
12VAC
24VAC
115VAC
AUXILIARY
TRANSFORMER FAN
MOTOR
Return to Section TOC
Return to Master TOC
GENERAL DESCRIPTION
The
INPUT LINE VOLTAGE, SWITCH AND MAIN TRANSFORMER
The
A reconnect panel and voltage range switch allow the user to configure the machine for either a low or high input voltage and also connect the auxiliary trans- former for the appropriate input voltage.
The auxiliary transformer develops the appropriate AC voltages to operate the cooling fan, the control board and the plasma output board.
Return to Section TOC
Return to Master TOC
NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.