F-27

F-27

TROUBLESHOOTING & REPAIR

(T2) AUXILIARY TRANSFORMER TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid elec- trical shock, please observe all safety notes and precautions detailed throughout this manu- al.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

DESCRIPTION

The test will determine if the auxiliary transformer is functional when the correct primary volt- age is applied to the primary winding.

MATERIALS NEEDED

Volt/ohmmeter Machine wiring diagram 5/16” Nut driver

230 VAC isolated power supply

This procedure takes approximately 18 minutes to perform.

PRO-CUT 80

Page 67