TROUBLESHOOTING & REPAIR

(T2) AUXILIARY TRANSFORMER TEST (continued)

TABLE F.6 - J21 AND J22 VOLTAGES

TEST POINT

TEST POINT

EXPECTED VOLTAGE

H1

H2 (5J22)

200 - 208VAC

H1

H4 (7J22)

380 - 415VAC

H1

H5 (8J22)

440 - 460VAC

Brown (8J21)

Brown (3J21)

12VAC

Red (2J21)

Red (6J21)

24VAC

Blue (9J21)

White (5J21)

18VAC

Blue (4J21)

White (5J21)

18VAC

Yellow (1J21)

Yellow (7J21)

115VAC

 

 

 

Return to

Return to Section TOC

Return to

Return to Master TOC

7.If the correct test voltages are present, the auxiliary transformer is good.

8.If any of the voltages are missing or very low with the proper primary voltage applied, the auxiliary transformer may be faulty.

9.If the auxiliary transformer tests good but it does not function when connected to the PRO-CUT 80, check the harness wiring to the auxiliary transformer. See the Wiring Diagram.

10.When finished with the test, replace plugs 21 and 22 and the case wraparound.