Lincoln Electric SVM146-A service manual Troubleshooting & Repair

Models: SVM146-A

1 110
Download 110 pages 45.11 Kb
Page 96
Image 96

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-56

F-56

TROUBLESHOOTING & REPAIR

INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)

7.Carefully remove the input rectifier bridge.

8.When installing a new input rectifier apply a thin coating of Penetrox A-13 Heat Sink Compound (Lincoln E2529) to the mating surfaces. Torque the mounting cap screws and nuts to 44 in-lbs.

9.Reconnect the 10 leads to the correct ter- minals and torque the phillips head screws to 31 in-lbs.

10.Apply Dow Corning 738 Insulating Com- pound to all six screw heads and termi- nals. The heavy input lead terminals should be against the rectifier terminals.

11.Assemble case wrap-around cover.

PRO-CUT 80

Page 96
Image 96
Lincoln Electric SVM146-A service manual Troubleshooting & Repair