Lincoln Electric SVM146-A service manual Figure F.15 Display Board Test Points

Models: SVM146-A

1 110
Download 110 pages 45.11 Kb
Page 79
Image 79

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-39

F-39

TROUBLESHOOTING & REPAIR

LOW VOLTAGE CIRCUIT TEST (continued)

FIGURE F.14 – CONTROL BOARD LEDs

PRO-CUT 80

G3443

PRO-CUT 55CONTROL G3328

LED2

LED1

LED3

Return to Section TOC

Return to Master TOC

CONTROL BOARD LED DEFINITIONS

LED1: (Red) This light indicates that 18 VAC is being supplied to the control board from the auxiliary transformer. It also shows that the 18 VAC is being rectified and should be regulated to +15 VDC. This +15 VDC supply is used to power the circuitry on the control board.

LED2: (Red) This light indicates that the +5.5 VDC is present. This voltage is derived from the +15 VDC supply. The +5.5 VDC supply is used to power the circuitry on the control board.

LED3: (Red) This light indicates that 18 VAC is being supplied to the control board from the auxiliary transformer. It also shows that the 18 VAC is being rectified and should be regulated to -15 VDC. This 15 VDC supply is used to power the circuitry on the control board.

Return to Section TOC

Return to Master TOC

FIGURE F.15 – DISPLAY BOARD TEST POINTS

L10721 DISPLAY BOARD

(REAR VIEW)

J 40

15

1

#216

#219

PRO-CUT 80

Page 79
Image 79
Lincoln Electric SVM146-A service manual Figure F.15 Display Board Test Points