INSTALLATION
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 80
GAS REQUIREMENTS
Required Gas Flow Rate | Required Gas Inlet Pressure |
70 PSI @ 480 SCHF | 80 to 150 PSI |
(4.8 Bar. @ 13550 LHR) | (5.4 Bar. to 10.2 Bar.) |
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all plasma cutting applications based on U.S. National Electrical Code
Ambient Temperature 30°C or Less
AC Input Voltage | Fuse (Super Lag) |
| Type 75°C |
at | Circuit Breaker | Copper Wire in Conduit AWG | |
60 Hertz | (Delay Type) |
| (IEC) Sizes |
|
|
|
|
230VAC Single Phase | 100 Amps | #4 (21.1mm2) | #4 (21.1mm2) |
460VAC Single Phase | 60 Amps | #8 (8.4mm2) | #8 (8.4mm2) |
230VAC Three Phase | 60 Amps | #8 (8.4mm2) | #8 (8.4mm2) |
460VAC Three Phase | 40 Amps | #10 (5.3mm2) | #10 (5.3mm2) |
| PHYSICAL | DIMENSIONS |
|
Height | Width | Depth | Weight with |
|
|
| Torch Cable |
16.5 Inches | 13.75 Inches | 29.5 Inches | 98 lbs. (44.5 kg.) |
419 mm | 349 mm | 749 mm | (25 ft. cable) |
|
|
| 113 lbs. (51.4 kg.) |
|
|
| (50 ft. cable) |
|
|
|
|