F-60

F-60

 

 

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

IDLE AMPS

Input Volts

Maximum Idle Amps

 

 

50 – 113 VDC

1 Amp

 

 

OPEN CIRCUIT VOLTAGES

Mode

Input Voltage

Open Circuit Voltage

 

 

 

CC Stick

72 – 113 VDC

74 – 78 VDC

CC Stick

60 – 72 VDC

Volts In + 4 VDC

CC Pipe (200 A preset)

72 – 113 VDC

73 – 78 VDC

CV Min. Preset

60 – 113 VDC

17 – 20 VDC

CV Max. Preset

60 – 113 VDC

50 – 54 VDC

 

 

 

LOAD TEST

Mode

Input Voltage

Output Amps and Volts

 

 

 

CC Stick/Gouge

60 – 113 VDC

100 Amps @ 24 VDC

CC Stick/Gouge

60 – 113 VDC

200 Amps @ 28 VDC

CC Stick/Gouge

60 – 113 VDC

350 Amps @ 34 VDC

 

 

 

FAN AS NEEDED (F.A.N.)

The fan should turn on when the machine is loaded and stay on for 50–70 seconds after the output load is removed.

MULTI-WELD 350

Page 100
Image 100
Lincoln Electric SVM151-A service manual Retest After Repair, Idle Amps, Open Circuit Voltages, Load Test