Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
|
| TROUBLESHOOTING & REPAIR |
RETEST AFTER REPAIR
Retest a machine:
•If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR
•If you repair or replace any electrical components.
IDLE AMPS
Input Volts | Maximum Idle Amps |
|
|
50 – 113 VDC | 1 Amp |
|
|
OPEN CIRCUIT VOLTAGES
Mode | Input Voltage | Open Circuit Voltage |
|
|
|
CC Stick | 72 – 113 VDC | 74 – 78 VDC |
CC Stick | 60 – 72 VDC | Volts In + 4 VDC |
CC Pipe (200 A preset) | 72 – 113 VDC | 73 – 78 VDC |
CV Min. Preset | 60 – 113 VDC | 17 – 20 VDC |
CV Max. Preset | 60 – 113 VDC | 50 – 54 VDC |
|
|
|
LOAD TEST
Mode | Input Voltage | Output Amps and Volts |
|
|
|
CC Stick/Gouge | 60 – 113 VDC | 100 Amps @ 24 VDC |
CC Stick/Gouge | 60 – 113 VDC | 200 Amps @ 28 VDC |
CC Stick/Gouge | 60 – 113 VDC | 350 Amps @ 34 VDC |
|
|
|
FAN AS NEEDED (F.A.N.)
The fan should turn on when the machine is loaded and stay on for