TROUBLESHOOTING & REPAIR

 

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

The meters do not light in either CV

1. In the CC mode, only the AMPS

1.

Check all the plug connections

or CC modes.

meter will light. In the CV mode,

 

to the Weld Control Board for

 

only the VOLTS meter will light.

 

loose or faulty connections.

 

 

 

See the Wiring Diagram.

 

 

2.

Check the leads and connec-

 

 

 

tions between the meters and

 

 

 

the Weld Control Board. See

 

 

 

the Wiring Diagram.

 

 

 

 

3.

Perform the

Analog

Control

 

 

 

Power Supply Board Test.

 

 

4.

The meters may be faulty.

 

 

5.

The Weld Control Board may be

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

One or both of the meter’s readings

1. Make sure the test or external

1.

Check shunt

feedback

leads

are not accurate.

meter is reliable and accurate.

 

R326, 327, R226, 227, plugs

 

 

 

P21 and P6 for loose or faulty

 

 

 

connections.

See the Wiring

 

 

 

Diagram.

 

 

 

 

 

2.

Check the integrity of lead 237

 

 

 

at plug P12 on the Weld Control

 

 

 

Board and also at plug P31 on

 

 

 

the Peripheral Board.

 

 

 

 

3.

See the Digital Meter Calibra-

 

 

 

tion and Adjustment Test in

 

 

 

the Maintenance section.

 

 

4.

Perform the

Analog

Control

 

 

 

Power Supply Board Test.

 

 

5.

The Weld Control Board may be

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

MULTI-WELD 350

Page 48
Image 48
Lincoln Electric SVM151-A Analog Control Power Supply Board Test, See the Digital Meter Calibra, Tion and Adjustment Test