F-17

F-17

 

 

TROUBLESHOOTING & REPAIR

INPUT CONTACTOR COIL RESISTANCE AND SUPPLY VOLTAGE TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

TEST DESCRIPTION

This test will determine if the input contactor is functioning properly.

MATERIALS NEEDED

Volt/Ohmmeter 3/8" Nut driver Needle nose pliers Wiring Diagram

External, isolated 40 VDC power supply

This procedure should take approximately 40 minutes to perform.

MULTI-WELD 350

Page 57
Image 57
Lincoln Electric SVM151-A service manual Input Contactor Coil Resistance and Supply Voltage Test