F-6

 

 

F-6

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

The Multi-Weld 350 does not have

1. Check the welding cables for

1. Check for loose or faulty con-

output. The meters turn on, the

loose or faulty connections.

nections at the Control box, the

input contactor activates and the

 

Chopper boards,

and the

Thermal light is off.

 

Analog Power Supply Board.

 

 

See the Wiring Diagram.

 

 

2. Check the heavy current carry-

 

 

ing leads at the choke, the

 

 

chopper boards, the shunt and

 

 

the output terminals for loose or

 

 

faulty connections.

See the

 

 

Wiring Diagram.

 

 

 

 

3. Perform the Chopper Board

 

 

Input Voltage and Resistance

 

 

Test.

 

 

 

 

4. Perform the Analog Control

 

 

Power Supply Board Test.

 

 

5. The Weld Control Board may be

 

 

faulty. Replace.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.

MULTI-WELD 350

Page 46
Image 46
Lincoln Electric SVM151-A service manual Input Voltage and Resistance, Test