TROUBLESHOOTING & REPAIR

 

 

 

TROUBLESHOOTING GUIDE

 

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

The preset amps (CC mode) or

1.

The panel Output Control is dis-

1.

The Output Control (R1) may be

volts (CV mode) are not adjustable.

 

abled when a remote control

 

faulty.

Check or replace.

Also

 

 

device is plugged into the 6-pin

 

check

associated leads

for

 

 

remote receptacle.

 

loose or faulty connections.

 

 

 

 

 

2.

Check all the plug connections

 

 

 

 

to the Weld Control Board for

 

 

 

 

loose

or faulty connections.

 

 

 

 

See the Wiring Diagram.

 

 

 

 

 

3.

The Weld Control Board may be

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

The preset range is not correct.

1.

The panel Output Control is dis-

1.

Make sure plug P3 is connected

 

 

abled when a remote control

 

securely to receptacle J3 on the

 

 

device is plugged into the 6-pin

 

Weld Control Board. See the

 

 

remote receptacle.

 

Wiring Diagram. Make certain

 

 

 

 

all the jumper leads are in place.

 

 

 

2.

Check all the plug connections

 

 

 

 

to the Weld Control Board for

 

 

 

 

loose

or faulty connections.

 

 

 

 

See the Wiring Diagram.

 

 

 

 

 

3.

The Weld Control Board may be

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.