TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The fan motor does not run when

1. Normal operation.

The Multi-

1. Carefully check for approxi-

the machine is turned on.

Weld 350 utilizes a Fan On

mately 40VDC at the fan motor

 

Demand system.

The fan

leads (303+ to 300-). This test

 

should activate when welding.

must be performed while the

 

 

 

machine is connected to a resis-

 

 

 

tive load or welding. If the

The fan does not run when welding.

1. The fan should turn on when the

40VDC is NOT present, check

 

arc starts and remain on for

the associated leads and plugs

 

about a minute after the arc is

for loose or faulty connections.

 

out.

 

See the Wiring Diagram. If the

 

 

 

correct voltage IS present and

 

 

 

the fan is not running, the fan

 

 

 

motor may be faulty.

 

 

 

2. If the correct voltage (40VDC) is

 

 

 

not present in the above test,

 

 

 

perform the DC Buss Supply

 

 

 

Board Test.

 

 

 

3. The Weld Control Board may be

 

 

 

faulty. Replace.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353.