Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR | ||
|
GAS SOLENOID
REMOVAL AND REPLACEMENT PROCEDURE (CONTINUED)
FIGURE F.12 – SOLENOID NUT AND HOSE
GAS SOLENOID
GAS HOSE
CONTROL BOX
LOCK NUT
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
CONTROL BOX COVER
PROCEDURE
1.Perform the Case Removal Procedure.
2.Remove the 5
3.Remove the 2 wires on the solenoid coil. See wiring diagram.
4.Using the pliers remove the gas hose. Be careful not to damage the hose. See Figure F.12.
5.Remove the lock nut holding the solenoid. See Figure F.12.
6.Remove the solenoid from the unit.
7.Install the new solenoid with the attached hardware.
8.Reconnect the gas hose.
9.Reconnect the wires to the solenoid coil.
10. Replace the control box cover.