A-4

INSTALLATION

A-4

 

 

 

 

 

CABLE CONNECTIONS

 

2. Remove the cylinder cap. Inspect the cylinder valves

 

and regulator for damaged threads, dirt, dust, oil or

 

 

There is one circular connector for the gun trigger on

grease. Remove dust and dirt with a clean cloth. DO

NOT ATTACH THE REGULATOR IF OIL, GREASE

the front of the LN-25™ PRO.

 

OR DAMAGE IS PRESENT! Inform your gas supplier

 

of this condition. Oil or grease in the presence of high

Table A.2

pressure oxygen is explosive

.

 

Return to Section TOC

Return to Master TOC

Function

Pin

Wiring

 

 

 

 

 

5-pin trigger

 

A

Trigger

connector for

 

B

Not used

push-guns

 

C

Common

only.

 

D

Not used

 

 

 

E

Not used

 

 

 

 

 

CB D E A

SHIELDING GAS CONNECTION

3.Stand to one side away from the outlet and open the cylinder valve for an instant. This blows away any dust or dirt which may have accumulated in the valve outlet.

4.Attach the flow regulator to the cylinder valve and tight- en the union nut(s) securely with a wrench. Note: if

connecting to 100% CO2 cylinder, insert regulator adapter between regulator and cylinder valve. If adapter is equipped with a plastic washer, be sure it is seated for connection to the CO2 cylinder.

5.Attach one end of the inlet hose to the outlet fitting of the flow regulator. Attach the other end to the welding system shielding gas inlet. Tighten the union nuts with a wrench.

6.Before opening the cylinder valve, turn the regulator adjusting knob counterclockwise until the adjusting spring pressure is released.

7.Standing to one side, open the cylinder valve slowly a fraction of a turn. When the cylinder pressure gage stops moving, open the valve fully.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

WARNING

CYLINDER may explode if damaged.

• Keep cylinder upright and chained to support.

Keep cylinder away from areas where it may be damaged.

Never lift welder with cylinder attached.

Never allow welding electrode to touch cylinder.

Keep cylinder away from welding or other live electrical circuits.

BUILD UP OF SHIELDING GAS MAY

HARM HEALTH OR KILL.

• Shut off shielding gas supply when not in use.

See American National Standard z-49.1, "Safety in Welding and Cutting” Published by the American Welding Society.

------------------------------------------------------------------------

Maximum inlet pressure is 100 psi. (6.9 bar.)

Install the shielding gas supply as follows:

1. Secure the cylinder to prevent it from falling.

8.The flow regulator is adjustable. Adjust it to the flow rate recommended for the procedure and process being used before making a weld.

WIRE DRIVE CONFIGURATION

(See Figure A.1)

CHANGING THE GUN RECEIVER BUSHING

WARNING

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the weld- ing power source before installation or changing drive rolls and/or guides.

Do not touch electrically live parts.

When inching with the gun trigger, electrode and drive mechanism are "hot" to work and ground and could remain energized several seconds after the gun trigger is released.

Do not operate with covers, panels or guards removed or open.

Only qualified personnel should perform mainte- nance work.

------------------------------------------------------------------------

LN-25™ PRO

Page 10
Image 10
Lincoln Electric SVM179-B service manual Wire Drive Configuration, Cable Connections, Shielding GAS Connection