F-4

TROUBLESHOOTING & REPAIR

F-4

 

 

 

 

 

 

 

 

 

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

Fault Code

 

 

Description

 

Possible Adjustment

 

 

 

 

 

 

Thermal LED Lit

1.

The wire drive motor has over-

1.

Remove any bends in the gun.

Motor overloaded, long term

 

heated.

2.

Check to see if the wire moves

 

 

 

(Err 81 on Digital Models)

 

 

 

 

smoothly through the gun and

 

 

 

 

cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Check the tightness of the spin-

 

 

 

 

 

 

dle brake.

 

 

 

 

 

 

4.

Wait for the motor to cool and

 

 

 

 

 

 

the error to reset.

 

 

 

 

 

 

Thermal LED Lit

1.

The wire drive motor is in a

1.

Verify that the motor can move

Motor overloaded, short term

 

locked state causing the motor

 

freely when the pressure arm is

 

to exceed it’s maximum amper-

 

released.

 

 

 

 

 

 

(Err 82 on Digital Models)

 

age draw.

2.

Verify that the drive system is

 

 

 

 

 

 

 

 

 

 

 

free of dirt and debris.

 

 

 

 

 

 

3.

Perform the MOTOR OVER-

 

 

 

 

 

 

LOAD TEST.

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

The feeder does not power up - no

1

The work sense lead has an

1.

Connect the work sense lead to

display (Digital Models) - no cold

 

open

or poor connection

 

the work in a location free of dirt

feed.

 

 

(across the arc model).

 

or paint.

 

NOTE: Both

LED’s should flash

2.

The power source is off.

2.

Turn on the power source.

 

briefly

when power is

3.

The circuit breaker for the feed-

3.

Reset the circuit breaker.

 

applied.

 

 

er on the power source may

 

 

 

 

 

 

 

 

 

 

 

 

have

tripped. (Control cable

 

 

 

 

 

 

model).

 

 

 

 

 

 

 

 

 

The wire feeder powers up but

1.

The contactor coil connections

1.

Verify the connections.

 

there is no welder output when the

 

are loose.

2.

Check for opens in the leads.

gun trigger is pulled. The shielding

 

 

 

2.

The contactor has failed.

 

 

 

gas flows and the drive rolls turn.

3.

Perform the CONTACTOR

 

 

 

(Across the arc models)

 

 

 

 

TEST, replace if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 