Lincoln Electric V205-T service manual SET UP Menu, Indicator Parameter Default

Models: V205-T

1 109
Download 109 pages 886 b
Page 21
Image 21

B-7

OPERATION

B-7

 

 

Return to Master TOC

SET UP MENU

Many additional parameters can be modified via the Set Up Menu. To access the Set Up Menu:

Position the ON/OFF switch to OFF “0”.

Depress and hold the Parameter select Push Button.

Position the On/Off switch to on "I" at the back of the machine; the input voltage light "Item 1" (green LED) confirms normal operation.

The SETUP mode is confirmed by a center "0" on the Digital display “Item 6”.

-Rotate the Output / Parameter Adjust Knob, the Digital Display shows the numbers corre- sponding to the parameters in sequence; stop at the desired parameter and push the "Setup/Parameter Push Button".

-The number on the Digital display "Item 6" is replaced by the value of the parameter that can be modified through the Output / Parameter adjust knob "Item 5".

-With parameter (9) all the modifications made in the SETUP mode are cancelled and the standard values set by Invertec V205-T AC/DC are restored.

-To exit the Set Up Menu, return to “0” and press the Setup/Parameter Push Button

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

INDICATOR

PARAMETER

 

DEFAULT

 

 

 

 

 

0

Exit From Set Up

 

 

 

1

Not Used

 

 

 

2

Pre Flow Time (0 - 25 seconds)

 

0.5 sec.

3

Arc Force, percent above Peak Current for Stick only (0 - 100%)

 

30%

 

4

Hot Start, percent above Peak Current for Stick only (0 - 100%)

 

80%

 

5

Setting of AC wave Form

 

2 (Square)

 

0 = Sinusoidal

 

 

 

 

1 = Triangular

 

 

 

 

2 = Square

 

 

 

 

NOTE: This parameter limits maximum weld current, see "OUTPUT LIMITATIONS" section of the manual.

 

 

 

6

Min. Weld Current Value with Remote Control,for TIG only.

 

10 Amps

 

(6 Amps - Value set for Indicator 7)

 

 

 

7

Max. Weld Current Value with Remote Control,for TIG only.

 

Peak Current

 

(Value set for Indicator 6 - Peak Current)

 

 

 

 

NOTE: Peak Current (Max Weld Current) can be limited by input voltage, welding mode, AC TIG waveform and AC TIG frequency.

 

 

 

8

Touch Start or H.F. Start in DC TIG (0 = H.F. Start, 1 = touch Start)

 

0

 

 

This parameter is ignored in AC TIG Mode

 

 

 

9

Reset all Parameters, (including control panel settings)

 

 

 

10

Not Used

 

 

 

11

Not Used

 

 

 

12

2 Step Trigger Selection

 

1

 

 

0 = Restart Disabled

 

 

 

 

1 = Restart Enabled

 

 

 

13

4 Step Trigger Selection

 

0

 

 

0 = Restart Disabled

 

 

 

 

1 = Restart Enabled

 

 

 

14

Start Power , for TIG only

 

2.0

 

 

This function sets the initial start energy limit.

 

 

 

 

(1.0 = min., 5.0 = max.)

 

 

 

 

Note: If the machine does not initiate a welding arc it will repeat the

 

 

 

 

starting sequence with an increased start energy up to this limit.

 

 

 

 

Set this number to a higher setting than the factory default if

 

 

 

 

needed to improve starting of large diameter tungstens electrodes.

 

 

 

 

 

 

 

 

 

V205-T AC/DC

 

 

Page 21
Image 21
Lincoln Electric V205-T service manual SET UP Menu, Indicator Parameter Default