Lincoln Electric V205-T Installation, Operating Temperature Range Storage Temperature Range

Models: V205-T

1 109
Download 109 pages 886 b
Page 8
Image 8

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-2

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

A-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - SINGLE PHASE ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltages / 50 /60 Hz.

 

 

 

 

 

 

 

Max. Input Current

 

 

 

 

 

 

115

 

 

 

 

 

 

 

 

34A at Rated Output

 

 

 

 

 

 

230

 

 

 

 

 

 

 

 

30A at Rated Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Amps

 

 

 

 

 

 

Output Amps

Volts at Rated Amperes

 

 

 

 

 

 

(115V)

35%

 

 

 

 

 

(Stick) 110

 

24.4V

 

 

 

 

 

34A

 

 

 

 

 

60%

 

 

 

 

 

90

 

23.6V

 

 

 

 

 

28A

 

 

 

 

 

100%

 

 

 

 

 

70

 

22.8V

 

 

 

 

 

20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(115V)

40%

 

 

 

 

 

(TIG) 150

 

16V

 

 

 

 

 

34A

 

 

 

 

 

60%

 

 

 

 

 

120

 

14.8V

 

 

 

 

 

25A

 

 

 

 

 

100%

 

 

 

 

 

100

 

14V

 

 

 

 

 

20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(230V)

35%

 

 

 

 

 

(Stick) 180

 

27.2V

 

 

 

 

 

30A

 

 

 

 

 

60%

 

 

 

 

 

150

 

26V

 

 

 

 

 

23A

 

 

 

 

 

100%

 

 

 

 

 

130

 

25.2V

 

 

 

 

 

19A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(230V)

40%

 

 

 

 

 

(TIG) 200

 

18V

 

 

 

 

 

30A

 

 

 

 

 

60%

 

 

 

 

 

170

 

16V

 

 

 

 

 

18A

 

 

 

 

 

100%

 

 

 

 

 

140

 

15.6V

 

 

 

 

 

15A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

Output Current

 

 

 

 

 

Maximum Open

 

 

 

 

 

Type of Output

 

 

 

 

Range

 

 

 

 

 

Circuit Voltage

 

 

 

 

 

 

 

 

 

 

6-200 Amps

 

 

 

 

 

54 Volts Max.

 

 

 

 

 

AC/DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

TYPE S, SO ST, STO, OR EXTRA

 

TIME-DELAY CIRCUIT BREAKER

 

 

 

VOLTAGE /

 

HARD USAGE INPUT CORD AWG

 

OR FUSE SIZE (AMPS)

 

 

 

FREQUENCY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(HZ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115/50/60

 

#12

 

 

 

 

 

 

 

 

30A

 

 

230/50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Width

 

 

 

 

 

Depth

 

Weight

 

 

 

 

15 in.

8.5 in.

 

 

 

 

 

19 in.

 

Approx. 38 lbs.

 

 

 

 

381 mm

216 mm

 

 

 

 

 

483 mm

 

17 kgs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

STORAGE TEMPERATURE RANGE

-20°C to +40°C

-50°C to +85°C

 

 

V205-T AC/DC