F-6

 

F-6

 

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

FUNCTION PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

Error code “E20”, “E24”, or “E25”

1. Any one of these codes indi-

1. The Control/Display Board is

 

is flashing on the digital display.

cates a memory error.

faulty. Replace.

The machine functions normally

1. Check for obstructions that

1. Check the fan fuse F3 located on

except the cooling fan does not

could prevent the fan from turn-

the Bus Board Replace if faulty.

operate.

ing.

 

 

 

2. Perform the Bus Board Test.

 

 

3. The Main IGBT Inverter Board

 

 

May be Faulty. Perform the

 

 

Main IGBT Inverter Board

 

 

Low Voltage Supply Test.

 

 

 

No High Frequency when the torch

1. Make sure the HF is in the

1. Check fuse F2 on the Bus

trigger is pulled and the machine is

active mode. See the Set-up

Board.

in the TIG mode.

Menu in this manual.

2. Check for 385VDC at Test

 

 

 

 

Points 9 and 20. See the Main

 

 

IGBT Inverter Board UPFR

 

 

Test.

 

 

3. Perform the Control/Display

 

 

Board Test.

 

 

4. The HF board may be faulty.

 

 

Replace.

 

 

 

Error code “E14” is flashing of the

1. This is an indication that the

1. Check for excessive welding

digital display

output inductance is too high.

cable length.

 

 

2. The Main IGBT Inverter Board

 

 

may be faulty.

 

 

3. The Superimposition Board may

 

 

be faulty.

 

 

4. The Control/Display Board may

 

 

be faulty.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).

V205-T AC/DC

Page 42
Image 42
Lincoln Electric V205-T service manual Function Problems