TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

FUNCTION PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

No or low output. Error code “E11”

1. “E11” is an indication that the

1. If the correct input voltage

is flashing on the digital display.

 

input voltage being applied is

 

230VAC or 115VAC is being

 

 

too high. Check for the correct

 

applied to the machine the Input

 

 

input voltage.

230VAC

or

 

Filter Board may be faulty.

 

 

115VAC.

 

 

 

 

 

Perform the Input Filter Board

 

 

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

2. The Main IGBT Inverter Board

 

 

 

 

 

 

 

 

May be Faulty. Perform the

 

 

 

 

 

 

 

 

Main IGBT Inverter Board Low

 

 

 

 

 

 

 

 

Voltage Supply Test.

 

 

 

 

 

No or low output. Error code

1.

“E12” is an indication that the

1.

If the correct input voltage

“E12” is flashing on the digital dis-

 

input voltage being applied is

 

230VAC or 115VAC is being

play.

 

too low. Check for the correct

 

applied to the machine, the

 

 

input voltage. 230VAC or

 

 

Input Filter Board may be

 

 

115VAC.

 

 

 

 

 

faulty. Perform the Input Filter

 

 

 

 

 

 

 

 

Board Test.

 

 

 

 

 

 

 

2. The Main IGBT Inverter Board

 

 

 

 

 

 

 

 

May be Faulty. Perform the

 

 

 

 

 

 

 

 

Main IGBT Inverter Board

 

 

 

 

 

 

 

 

Low Voltage Supply Test.

 

 

 

 

 

No output. Error code “E10” is

1.

The welding application may be

1.

One of the thermal devices may

flashing on the digital display. The

 

exceeding

the

recommended

 

be faulty.

Check and replace if

thermal indicator light is on.

 

duty cycle.

 

 

 

 

 

necessary.

See the Wiring

 

 

 

 

 

 

 

 

Diagram.

 

 

2. Dirt and dust may have clogged

 

 

 

 

 

the cooling channels inside the

2. The Main IGBT Inverter Board

 

 

machine.

Refer

to

the

 

may be faulty.

 

 

Maintenance Section

in

this

 

 

 

 

 

manual.

 

 

 

 

 

 

 

 

3. The air intake and exhaust lou-

 

 

 

 

 

vers may be blocked due in

 

 

 

 

 

inadequate

clearance

around

 

 

 

 

 

the machine.

 

 

 

 

 

 

 

4. Make sure the cooling fan is

 

 

 

 

 

operating correctly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353(WELD).