F-41

F-41

TROUBLESHOOTING AND REPAIR

SECONDARY POWER BOARD TEST (continued)

FIGURE F.20 SECONDARY POWER BOARD TEST POINT LOCATIONS

10K Ohms 10K Ohms

GA SA SB GB

I I I I

3

2

1

TABLE F.13 VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE

Generator/Mode

Test Point

Value

 

 

 

ON/STICK

GA[+],SA[-]

-13 VDC

 

 

 

ON/STICK

GB[+],SB[-]

+13 VDC

 

 

 

ON/STICK

3[+],1[-]

+ 0.5 VDC

 

 

 

ON/STICK

1[+]2[-]

+ 105 VDC

 

 

 

ON/STICK

OCV

+ 52 VDC

 

 

 

OFF/-

R GA-SA

10 K Ohms

 

 

 

OFF/-

R GB-SB

10 K Ohms

 

 

 

V205-T AC/DC

Page 77
Image 77
Lincoln Electric V205-T service manual Figure F.20 Secondary Power Board Test Point Locations