Chapter 5 | Configuration Using the |
Broadcast Packets Displays the number of good Broadcast packets received on the interface since the device was last refreshed. This number does not include Multicast packets.
Multicast Packets Displays the number of good Multicast packets received on the interface since the device was last refreshed.
CRC Align Errors Displays the number of CRC and Align errors that have occurred on the interface since the device was last refreshed.
Undersize Packets Displays the number of undersized packets (less than 64 octets) received on the interface since the device was last refreshed.
Oversize Packets Displays the number of oversized packets (over 1518 octets) received on the interface since the device was last refreshed.
Fragments Displays the number of fragments (packets with less than 64 octets, excluding framing bits, but including FCS octets) received on the interface since the device was last refreshed.
Jabbers Displays the total number of received packets that were longer than 1518 octets. This number excludes frame bits, but includes FCS octets that had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a
Collisions Displays the number of collisions received on the interface since the device was last refreshed.
Utilization Displays the percentage of the interface utilized.
Statistics > RMON Alarms
The RMON Alarm screen is used to set network alarms. Network alarms occur when a network problem, or event, is detected. Rising and falling thresholds generate events.
Statistics > RMON Alarm
Add Alarm
Alarm Entry Indicates a specific alarm.
Interface Indicates the interface for which RMON statistics are displayed. To specify the interface, select Unit No. (default) and specify the unit number and port from the
Counter Name Displays the selected MIB variable.
Sample Type Defines the sampling method for the selected variable and comparing the value against the thresholds. The possible field values are:
•Absolute Compares the values directly with the thresholds at the end of the sampling interval.
•Delta Subtracts the last sampled value from the current value. The difference in the values is compared to the threshold.
Rising Threshold Displays the rising counter value that triggers the rising threshold alarm. The rising threshold is presented on top of the graph bars. Each monitored variable is designated a color.
Rising Event Displays the mechanism in which the alarms are reported. The possible field values are:
•LOG Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.
•TRAP Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.
•Both Indicates that both the Log and Trap mechanism are used to report alarms.
Falling Threshold Displays the falling counter value that triggers the falling threshold alarm. The falling threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.
Falling Event Displays the mechanism in which the alarms are reported. The possible field values are:
•LOG Indicates there is not a saving mechanism for either the device or in the management system. If the device is not reset, the entry remains in the Log Table.
•TRAP Indicates that a SNMP trap is generated, and sent via the Trap mechanism. The Trap can also be saved using the Trap mechanism.
•Both Indicates that both the Log and Trap mechanism are used to report alarms.
Startup Alarm Displays the trigger that activates alarm generation. Rising is defined by crossing the threshold from a
26 |