Chapter 5 Linksys IP Phone Field Reference

SIP Tab

Response Status Code Handling

Field

Description

 

 

SIT1 RSC

SIP response status code for the appropriate Special Information Tone (SIT). For example,

 

if you set the SIT1 RSC to 404, when the user makes a call and a failure code of 404 is

 

returned, the SIT1 tone is played. Reorder or Busy Tone is played by default for all

 

unsuccessful response status code for SIT 1 RSC through SIT 4 RSC.

 

Defaults to blank.

 

 

SIT2 RSC

SIP response status code to INVITE on which to play the SIT2 Tone.

 

Defaults to blank.

 

 

SIT3 RSC

SIP response status code to INVITE on which to play the SIT3 Tone.

 

Defaults to blank.

 

 

SIT4 RSC

SIP response status code to INVITE on which to play the SIT4 Tone.

 

Defaults to blank.

 

 

Try Backup RSC

SIP response code that retries a backup server for the current request.

(not applicable to SPA901)

Defaults to blank.

 

 

 

Retry Reg RSC

Interval to wait before the Linksys IP phone retries registration after failing during the last

(not applicable to SPA901)

registration.

Defaults to blank.

 

 

 

RTP Parameters

Field

Description

 

 

RTP Port Min

Minimum port number for RTP transmission and reception. <RTP Port Min> and <RTP

 

Port Max> should define a range that contains at least 4 even number ports, such as 100 – 106.

 

Defaults to 16384.

 

 

RTP Port Max

Maximum port number for RTP transmission and reception.

 

Defaults to 16482.

 

 

RTP Packet SizeSPA901

Packet size in seconds, which can range from 0.01 to 0.16. Valid values must be a multiple

(not applicable to SPA901)

of 0.01 seconds.

Defaults to 0.030.

 

 

 

Max RTP ICMP Err

Number of successive ICMP errors allowed when transmitting RTP packets to the peer

(not applicable to SPA901)

before the Linksys IP phone terminates the call. If value is set to 0, the Linksys IP phone

ignores the limit on ICMP errors.

 

 

Defaults to 0.

 

 

 

 