Linksys SPA 900 manual Regional Tab, Call Progress Tones

Models: SPA 900

1 165
Download 165 pages 13.37 Kb
Page 124
Image 124

Chapter 5 Linksys IP Phone Field Reference

Regional Tab

Regional Tab

This section describes the fields for the following headings on the Regional tab:

Call Progress Tones, page 5-19

Distinctive Ring Patterns, page 5-20

Control Timer Values (sec), page 5-21

Vertical Service Activation Codes, page 5-22

Vertical Service Activation Codes, page 5-22

Outbound Call Codec Selection Codes, page 5-25

Miscellaneous, page 5-27

Call Progress Tones

Note None of the following parameters apply to the SPA901.

Field

Description

 

 

Dial Tone

Prompts the user to enter a phone number.

 

Defaults to 350@-19,440@-19;10(*/0/1+2).

 

 

Outside Dial Tone

Alternative to the Dial Tone. It prompts the user to enter an external phone number, as

 

opposed to an internal extension. It is triggered by a, (comma) character encountered in

 

the dial plan.

 

Defaults to 420@-16;10(*/0/1).

 

 

Prompt Tone

Prompts the user to enter a call forwarding phone number.

 

Defaults to 520@-19,620@-19;10(*/0/1+2).

 

 

Busy Tone

Played when a 486 RSC is received for an outbound call.

 

Defaults to 480@-19,620@-19;10(.5/.5/1+2).

 

 

Reorder Tone

Played when an outbound call has failed or after the far end hangs up during an established

 

call. Reorder Tone is played automatically when <Dial Tone> or any of its alternatives

 

times out.

 

Defaults to 480@-19,620@-19;10(.25/.25/1+2).

 

 

Off Hook Warning Tone

Played when the caller has not properly placed the handset on the cradle. Off Hook

 

Warning Tone is played when Reorder Tone times out.

 

Defaults to 480@10,620@0;10(.125/.125/1+2).

 

 

Ring Back Tone

Played during an outbound call when the far end is ringing.

 

Defaults to 440@-19,480@-19;*(2/4/1+2).

 

 

Call Waiting Tone

Played when a call is waiting. Defaults to 440@-10;30(.3/9.7/1)

 

 

 

 

Linksys IP Phone Administrator Guide

 

 

 

 

 

 

Firmware Version 5.1

 

 

5-19

 

 

 

 

 

Page 124