Installation & Service Manual
1Determine water heater location (continued)
Figure
1" MINIMUM CLEARANCE AROUND HOT WATER PIPES AND VENT PIPE
WARNING
6"
For closet installations, CPVC material MUST BE used in a closet structure due to elevated temperatures. Failure to follow this warning could result in fire, personal injury, or death.
VENTILATING
AIR OPENING
RECOMMENDED SERVICE CLEARANCES:
Top - | 18" (457 mm) |
Right Side - | 24" (610 mm) |
Front - | 24" (610 mm) |
CLOSED DOOR
VENTILATING
AIR OPENING
6"
*AREA OF EACH OPENING:
1 SQ. INCH PER 1000 BTU PER HOUR INPUT WITH A MINIMUM OF 100 SQ. INCHES
Figure
1" MINIMUM CLEARANCE AROUND HOT WATER PIPES AND VENT PIPE
RECOMMENDED SERVICE CLEARANCES:
Top - | 18" (457 mm) |
Right Side - | 24" (610 mm) |
Front - | 24" (610 mm) |
WARNING
For alcove installations, CPVC material MUST BE used in an alcove structure due to elevated temperatures. Failure to follow this warning could result in fire, personal injury, or death.
OPEN
FRONT