Lochinvar SNA285-125 Description, Troubleshooting, Fault, Corrective Action, Flame, Sequence

Models: SNA400-125 SNR150-100 SNA285-125 SNR200-100 SNA500-125

1 72
Download 72 pages 52.95 Kb
Page 62
Image 62
DESCRIPTION

TM

Installation & Service Manual

13 Troubleshooting

Table 13E Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface

FAULT

DESCRIPTION

CORRECTIVE ACTION

 

 

 

Flame

 

• Check supply voltage for proper polarity.

 

 

Sequence

 

• Check external wiring for voltage feedback.

(will require a manual

The flame detector circuit is seeing a flame

• Check the flame rod and make sure it is clean.

reset once the condition

signal while no flame is present.

 

has been corrected.

 

• Check the internal wiring for bad connections.

Press the RESET button

 

• Replace main control board.

on the display to reset.)

 

 

 

 

 

 

• Inspect spark electrode and associated wiring for

 

 

damage and connection. Reference page 56 of this

 

 

manual for removal and cleaning procedures.

 

 

Replace if necessary.

 

 

• Check for proper electrical grounding of the unit.

 

 

• Check incoming supply gas pressure. Natural gas

 

 

pressures should be between 4 - 14 inches w.c. and

 

 

LP gas pressures should be between 8 - 14

 

 

inches w.c. Refer to Section 7 - Gas Connections for

 

 

detailed information concerning the gas supply.

 

 

• Verify that the plastic hose from the gas valve to the

 

 

air inlet is connected and is not damaged.

 

 

• Verify that the vent/air intake pipes are correctly

 

 

installed and that there are no obstructions.

 

 

• Check for 24 VAC to the gas valve at the 2-pin

 

 

connection on the side of the main control board

No Flame Ign

 

during the ignition attempt. If no voltage is present,

 

replace the main control board.

(will require a manual

 

• If 24 VAC is present at the main control board, check

reset once the condition

The unit has failed to prove main burner

has been corrected.

ignition after four (4) attempts.

the wiring between the main control board and the

gas valve. Replace the wiring if necessary. Do not

Press the RESET button

 

 

disconnect the wiring from the gas valve and attempt

on the display to reset.)

 

 

to measure voltage at that point. The main control

 

 

 

 

board can detect if the gas valve is not connected and

 

 

will display the GV / Relay Fail fault.

 

 

• If 24 VAC is present, check the outlet of the valve to

 

 

ensure the valve is flowing gas. With a manometer

 

 

connected to the outlet tap of the gas valve, when the

 

 

unit is in the prepurge period, there should be a

 

 

negative pressure present. When the valve is

 

 

energized a change in pressure should occur. If the

 

 

pressure change does not occur, the gas valve is not

 

 

opening. Replace the gas valve.

 

 

• Inspect flame sensor and associated wiring.

 

 

Reference page 56 of this manual for removal and

 

 

cleaning procedures. Replace if necessary.

 

 

• Inspect the burner. Reference page 56 of this manual

 

 

for removal and cleaning procedures. Replace if

 

 

necessary.

 

 

• Replace the main control board.

 

 

 

Flame 62 Sequence

Page 62
Image 62
Lochinvar SNA285-125 Description, Troubleshooting, Fault, Corrective Action, Installation & Service Manual, Flame