13 Troubleshooting
Table 13E Troubleshooting Chart - Fault Messages Displayed on Water Heater Interface
FAULT | DESCRIPTION | CORRECTIVE ACTION | |
|
|
| |
Flame |
| • Check supply voltage for proper polarity. | |
|
| ||
Sequence |
| • Check external wiring for voltage feedback. | |
(will require a manual | The flame detector circuit is seeing a flame | • Check the flame rod and make sure it is clean. | |
reset once the condition | signal while no flame is present. |
| |
has been corrected. |
| • Check the internal wiring for bad connections. | |
Press the RESET button |
| • Replace main control board. | |
on the display to reset.) |
| ||
|
|
| |
|
| • Inspect spark electrode and associated wiring for | |
|
| damage and connection. Reference page 56 of this | |
|
| manual for removal and cleaning procedures. | |
|
| Replace if necessary. | |
|
| • Check for proper electrical grounding of the unit. | |
|
| • Check incoming supply gas pressure. Natural gas | |
|
| pressures should be between 4 - 14 inches w.c. and | |
|
| LP gas pressures should be between 8 - 14 | |
|
| inches w.c. Refer to Section 7 - Gas Connections for | |
|
| detailed information concerning the gas supply. | |
|
| • Verify that the plastic hose from the gas valve to the | |
|
| air inlet is connected and is not damaged. | |
|
| • Verify that the vent/air intake pipes are correctly | |
|
| installed and that there are no obstructions. | |
|
| • Check for 24 VAC to the gas valve at the | |
|
| connection on the side of the main control board | |
No Flame Ign |
| during the ignition attempt. If no voltage is present, | |
| replace the main control board. | ||
(will require a manual |
| • If 24 VAC is present at the main control board, check | |
reset once the condition | The unit has failed to prove main burner | ||
has been corrected. | ignition after four (4) attempts. | the wiring between the main control board and the | |
gas valve. Replace the wiring if necessary. Do not | |||
Press the RESET button |
| ||
| disconnect the wiring from the gas valve and attempt | ||
on the display to reset.) |
| ||
| to measure voltage at that point. The main control | ||
|
| ||
|
| board can detect if the gas valve is not connected and | |
|
| will display the GV / Relay Fail fault. | |
|
| • If 24 VAC is present, check the outlet of the valve to | |
|
| ensure the valve is flowing gas. With a manometer | |
|
| connected to the outlet tap of the gas valve, when the | |
|
| unit is in the prepurge period, there should be a | |
|
| negative pressure present. When the valve is | |
|
| energized a change in pressure should occur. If the | |
|
| pressure change does not occur, the gas valve is not | |
|
| opening. Replace the gas valve. | |
|
| • Inspect flame sensor and associated wiring. | |
|
| Reference page 56 of this manual for removal and | |
|
| cleaning procedures. Replace if necessary. | |
|
| • Inspect the burner. Reference page 56 of this manual | |
|
| for removal and cleaning procedures. Replace if | |
|
| necessary. | |
|
| • Replace the main control board. | |
|
|
|
62