2.2.2.4 Thermal and Atmospheric Characteristics

The following parameters define the thermal and atmospheric environment for the LSI7202CP during normal operation:

Temperature range: 0 ° C to 55 ° C (dry bulb)

Relative humidity range: 5% to 90% noncondensing

Maximum dew point temperature: 32 ° C

Airflow must be sufficient to keep the LSIFC929 heat sink temperature below 65 ° C

The following parameters define the storage and transit environment for the LSI7202CP:

Temperature range: 40 ° C to +105 ° C (dry bulb)

Relative humidity range: 5% to 90% noncondensing

2.2.2.5Electromagnetic Compliance

The design of the LSI7202CP minimizes electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The LSI7202CP carries the BSMI, CE mark, FCC Self- Certification log, Canadian Compliance Statement, VCCI, and meets the requirements of FCC Class A.

2.2.2.6 Safety Characteristics

The LSI7202CP meets or exceeds the requirements of Underwriters Laboratory (UL) flammability rating 94 V0. The LSI7202CP is also marked with the supplier’s name or trademark, type, and UL flammability rating.

2-6

LSI7202CP Host Adapter Characteristics

Copyright © 2001, 2002 by LSI Logic Corporation. All rights reserved.