If these devices are not listed, check that the adapter is correctly installed, and re-seat the adapter if necessary.

4.2.2 Method 2 - Using the probe-scsi-allCommand

Step 1. Access the ok prompt.

Type the probe-scsi-allcommand:

Step 2. The system then displays output similar to this:

ok probe-scsi-all

/pci@8,600000/SUNW,qlc@4

LiD HA LUN

---Port WWN---

----Disk description----

1 1 0 2100002037e4d65b SEAGATE ST318304FSUN18G 0726

/pci@8,700000/IntraServer-Ultra160,scsi@3,1 /pci@8,700000/IntraServer-Ultra160,scsi@3

Target 0

 

 

 

Unit 0

Disk IBM

DDRS-34560D

DC1B

/pci@8,700000/IntraServer,fc@2

MPT Version 1.00, Firmware Version 1.02.00

Target 0

Unit 0 Disk SEAGATE ST39173FC 6615

WWN 2100002037109d76 Port ID d9

Target 1

Unit 0 Disk SEAGATE ST39173FC 6258

WWN 210000203710565a Port ID 17

Target 2

Unit 0 Disk SEAGATE ST39173FC 6258

WWN 2100002037105212 Port ID 1

Target 3

Unit 0 Disk SEAGATE ST39173FC 6258

WWN 2100002037103da8 Port ID 26

Target 4

Unit 0 Disk SEAGATE ST39173FC 6258

WWN 210000203710324a Port ID 73

/pci@8,700000/scsi@6

Target 6

Unit 0 Removable Read Only device PLEXTOR CD-ROM PX-20TS

Verifying the Installation

4-3