Chapter 4

Solaris Software

Requirements

This chapter provides device driver requirements and methods to verify the proper installation of the LSI7202CP, as well as installation instructions for the itmpt Sun SPARC Solaris driver. The chapter includes these topics:

Section 4.1, “Device Driver Software Requirements,” page 4-1

Section 4.2, “Verifying the Installation,” page 4-1

Section 4.3, “itmpt Device Driver,” page 4-4

4.1Device Driver Software Requirements

To support the device drivers for the LSI7202CP, you must have the itmpt driver for your operating system installed.

After they are installed, the boards have device paths similar to this example:

/pci@8,700000/IntraServer,fc@1

Under these nodes, one instance of the device driver that has device nodes is evident:

/pci@8,700000/IntraServer,fc@1,1/disk

/pci@8,700000/IntraServer,fc@1,1/tape

4.2 Verifying the Installation

To verify the proper installation of the LSI7202CP before booting the operating system, follow one of these two methods.

LSI7202CP CompactPCI Dual Channel 2 Gbit/s Fibre Channel Host Adapter 4-1