ok 1 clear-persistent

Entry 1 has been cleared

ok show-persistent

ok

Entry 1 has been deleted from the table, and the table is now empty.

3.2 Troubleshooting

The LSI Logic Intel BIOS Configuration Utility is a powerful tool. If, while using it, you somehow disable all of your controllers, pressing Ctrl-Aor Ctrl-Eafter memory initialization during reboot allows you to re-enable and reconfigure.

These messages may appear during the boot process:

Adapter removed from boot order, parameters will be updated accordingly! appears when an adapter is removed from the system or relocated behind a PCI bridge. This message is for information only, and no further user action is required.

Configuration data invalid, saving default configuration! appears if none of the information in NonVolatile Random Access Memory (NVRAM) is valid. This message is for information only, and can occur when the BIOS is upgraded or when some external event has rendered the NVRAM temporarily unreadable.

Found FC Controller not in following Boot Order List, to Add: Press Ctrl-C to start LSI Logic Configuration Utility... appears when fewer than four adapters are in the boot order and adapters exist in the system which are not in the boot order. This message is for information only, and indicates that more than four adapters exist in the system. The additional adapters will not be managed by the Configuration Utility.

3-14

BIOS Features

Copyright © 2001, 2002 by LSI Logic Corporation. All rights reserved.