LSI Corporation | September 2010 Page 71
LSISAS6160 SAS Switch User Guide Chapter 4: SAS Domain Manager Command Line Interface | Sample Output for Show Com-
mand
030 T - Enabled 6.0 * 5000c500176a32cd 000 End 000000010
031 T - Enabled 6.0 * 5000c500176c9211 000 End 000000010
032 T - Enabled 6.0 - Poydras 016 Switch 000001000
033 T - Enabled 6.0 - Poydras 017 Switch 000001000
034 T - Enabled 6.0 - Poydras 018 Switch 000001000
035 T - Enabled 6.0 - Poydras 019 Switch 000001000
036 D * Enabled 6.0 - 50012be0000380fd 000 End 010100010
037 D * Enabled - - ---------------- --- None 000000100
4.3.8 show phy <alias>: <phy> SDMCLI> show phy Lincoln:01
===============================================
Phy Information
===============================================
SAS Address: 500605b0000282bf
Phy Identifier: 01
State: Enabled
Link Speed: 6.0 Gb/s
Virtual Phy: No
Routing Attribute: Subtractive
Minimum Link Speed: 1.5 Gb/s
Maximum Link Speed: 6.0 Gb/s
Supported Minimum Link Speed: 1.5 Gb/s
Supported Maximum Link Speed: 6.0 Gb/s
Connector Type: No Information
Connector Element Index: 00
Connector Physical Link: 00
Phy Fault LED: OFF
Phy Change Count: 2
SAS Zone Group: Zoning Inactive
- Attached Device Information -
Attached SAS Address: 500605b0006b75c0
Attached Phy Identifier: 06
Attached Device Type: End Device
Attached Device Capabilities: SAS Management Initiator
SATA Initiator (SAS Tunneled)
SAS Initiator
- Error Statistics -
Invalid Dword Count: 0
Running Disparity Error Count: 0
Loss of Dword Synchronization Count: 0
Phy Reset Problem Count: 0
4.3.9 show version SDMCLI> show version
SDM-CLI Version 2.250.5.0
SDM-D Version 2.250.5.0