PDxx01

RS-232C Control Specification

Page: 10 / 49

Document Version [1.0]

5-7.CONTRAST Gain Data

Function

The external control equipment changes the CONTRAST gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

DATA02: CONTRAST Gain

CCH: -52

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

14H: +20

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: CONTRAST Gain Flag

07H

5-8.BRIGHT Gain Data

Function

The external control equipment changes the BRIGHT gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BRIGHT Gain Flag

08H

DATA02: BRIGHT Gain

E0H: -32

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

20H: +32

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BRIGHT Gain Flag

08H

Company Restricted

Page 10
Image 10
Marantz PDxx01 specifications Contrast Gain Data, Bright Gain Data