PDxx01 | Page: 24 / 49 |
Document Version [1.0]
5-37. RGB Select
Function
The external control equipment sets the RGB SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8BH 01H DATA00 CKS
DATA00 | 01H: AUTO |
| 11H: type1 |
| 12H: type2 |
| 13H: type3 |
| 14H: type4 |
| 15H: type5 |
| 16H: type6 |
| 17H: type7 |
| 18H: type8 |
| 19H: type9 |
| 1AH: type10 |
ACK
7FH 60H 80H 8BH 01H DATA00 CKS
DATA00 | 01H: AUTO |
| 11H: type1 |
| 12H: type2 |
| 13H: type3 |
| 14H: type4 |
| 15H: type5 |
| 16H: type6 |
| 17H: type7 |
| 18H: type8 |
| 19H: type9 |
| 1AH: type10 |
Correspond to Analog RGB.
The type is following as below.
HD_MODE1 :10KHz 以下 HD_MODE2 :14.0~20.9KHz HD_MODE3 :21.0~26.4KHz HD_MODE4 :26.5~32.7KHz HD_MODE5 :32.8~36.6KHz HD_MODE6 :36.7~38.5KHz HD_MODE7 :38.6~45.9KHz HD_MODE8 :46.0~49.0KHz HD_MODE9 :49.1~55.0KHz HD_MODE10:55.1~76.9KHz HD_MODE11:77.0~83.5KHz HD_MODE12:83.6~115.0KHz HD_MODE13: other
VD_MODE1:15.00~24.50Hz
VD_MODE2:24.60~27.50Hz
VD_MODE3:27.60~40.00Hz
VD_MODE4:40.01~48.50Hz
VD_MODE5:48.60~55.00Hz
VD_MODE6:55.01~61.76Hz
VD_MODE7:61.77~73.50Hz
VD_MODE8:73.51~79.50Hz
VD_MODE9:79.51~92.50Hz
VD_MODE10:92.51~110.00Hz
VD_MODE11:110.01~131.00Hz
VD_MODE12: other
Company Restricted