PDxx01

RS-232C Control Specification

Page: 16 / 49

Document Version [1.0]

5-19.TREBLE Gain Data

Function

The external control equipment changes the TREBLE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

DATA02: TREBLE Gain

F3H: -13

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

0DH: +13

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H

5-20.BALANCE Gain Data

Function

The external control equipment changes the BALANCE gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

 

DATA00: USER PICTURE Gain Flag

05H

 

DATA01: BALANCE Gain Flag

02H

 

DATA02: BALANCE Gain

EAH: -22

 

 

:

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

:

 

 

16H: +22

ACK

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

05H

 

DATA01: BALANCE Gain Flag

02H

Company Restricted

Page 16
Image 16