PDxx01

RS-232C Control Specification

Page: 20 / 49

Document Version [1.0]

5-28.CLOCK (PICTURE ADJUST) Gain Data

Function

The external control equipment changes the CLOCK gain data (ratio of frequency division) of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: CLOCK Gain Flag

04H

DATA02: CLOCK Gain

C0H: -64

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

40H: +64

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: CLOCK Gain Flag

04H

5-29.OSM ADJ. POSITION Data

Function

The external control equipment sets the position of the OSM menu of the plasma monitor.

Transmission Data

DFH 80H 60H 1AH 02H DATA00 DATA01 CKS

DATA00: OSM ADJ. Gain Flag

02H

DATA01

01H: 1(TOP LEFT)

 

02H: 2(TOP CENTER)

 

03H: 3(TOP RIGHT)

 

04H: 4(BOTTOM LEFT)

 

05H: 5(BOTTOM CENTER)

 

06H: 6(BOTTOM RIGHT)

ACK

7FH 60H 80H 1AH 01H DATA00 CKS

DATA00: OSM ADJ. Gain Flag

02H

5-30.POWER MGT Select

Function

The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.

Transmission Data

DFH 80H 60H 1AH 02H DATA00 DATA01 CKS

 

DATA00: POWER MGT Select

03H

 

DATA01

01H: ON

 

 

02H: OFF

ACK

 

 

 

 

7FH 60H 80H 1AH 02H DATA00 DATA01 CKS

 

DATA00: POWER MGT Select

03H

 

DATA01

01H: ON

 

 

02H: OFF

Company Restricted

Page 20
Image 20
Marantz PDxx01 Clock Picture Adjust Gain Data, OSM ADJ. Position Data, Power MGT Select, 7FH 60H 80H 1AH 01H DATA00 CKS