PDxx01

RS-232C Control Specification

Page: 17 / 49

Document Version [1.0]

5-21.SCREEN MODE Select

Function

The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH 80H 60H 51H 01H DATA00 CKS

DATA00 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: ANAMORHIC (FULL)

06H: REAL

08H: UNDERSCAN

09H: 14:9

0AH: 2.35:1

ACK

7FH 60H 80H 51H 01H DATA00 CKS

DATA00 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: ANAMORHIC(FULL)

06H: REAL

08H: UNDERSCAN

09H: 14:9

0AH: 2.35:1

*If it selects DATA00 “08: UNDERSCAN”, it need to set No.78 UNDERSCAN setting ON.

5-22.V. POSITION Gain Data

Function

The external control equipment changes the V. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

 

DATA00: USER PICTURE Gain Flag

03H

 

DATA01: V.POSITION Gain Flag

01H

 

DATA02: V.POSITION Gain

C0H: -64

 

 

:

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

:

 

 

40H: +64

ACK

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

03H

 

DATA01: V.POSITION Gain Flag

01H

Company Restricted

Page 17
Image 17
Marantz PDxx01 specifications Screen Mode Select, 22.V. Position Gain Data, DFH 80H 60H 51H 01H DATA00 CKS