PDxx01

RS-232C Control Specification

Page: 48 / 49

Document Version [1.0]

5-76.REMOTE CODE SETTING

Function

Remotecontroler codes are set.

Transmission Data

DFH 80H 60H 2BH 01H DATA00 CKS

DATA00

00H: ALL

 

01H: CODE1

 

02H: CODE2

 

03H: CODE3

 

04H: CODE4

ACK

7FH 60H 80H 2BH 01H DATA00 CKS

DATA00

00H: ALL

 

01H: CODE1

 

02H: CODE2

 

03H: CODE3

 

04H: CODE4

5-77.VOLUME Gain Data REQUEST

Function

The external control equipment inquires the volume gain for Plasma diaplay.

Transmission Data

1FH 80H 60H 0EH 00H CKS

ACK

DFH 60H 80H 0EH 01H DATA00 CKS

DATA00: VOLUME Gain

: 00H~2AH

 

(00H: 00FH:1510H:161FH31・・・2AH:42)

 

: FFH: MUTE

5-78.UNDER SCAN SETTING

Function

Under scan are set up.

Transmission Data

DFH 80H 60H 22H 01H DATA00 CKS

DATA00: 00H OFF

01H ON

ACK

7FH 60H 80H 22H 01H DATA00 CKS

DATA00: 00H OFF

01H ON

Company Restricted

Page 48
Image 48