PDxx01

RS-232C Control Specification

Page: 22 / 49

Document Version [1.0]

5-34.SCREEN WIPER Set

Function

The external control equipment sets the SCREEN WIPER of the plasma monitor.

Transmission Data

 

 

 

DFH 80H 60H C8H 04H

DATA00 to DATA03 CKS

 

DATA00: SCREEN WIPER

00H: No operation

 

 

01H: ON

 

 

02H: OFF

 

DATA01:

00H: fixed

 

DATA02:

FFH: fixed

 

DATA03:

01H: fixed

ACK

 

 

 

3FH 60H 80H C8H 00H

CKS

 

5-35.ALL RESET

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH 80H 60H 54H 00H CKS

ACK

3FH 60H 80H 54H 00H CKS

Company Restricted

Page 22
Image 22
Marantz PDxx01 specifications Screen Wiper Set, ALL Reset