PDxx01

RS-232C Control Specification

Page: 14 / 49

Document Version [1.0]

5-15.GREEN Gain Data

Function

The external control equipment changes the GREEN Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

DATA02: GREEN Gain1 (Bias)

D8H: -40

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

1EH: +30

DATA03: GREEN Gain2(Drive)

D8H : -40

 

:

 

FFH: -01

 

00H: 0

 

01H: +01

 

:

 

1EH: +30

ACK

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

5-16.BLUE Gain Data

Function

The external control equipment changes the BLUE Gain Data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS

 

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: BLUE Gain Flag

03H

 

DATA02: BLUE Gain1 (Bias)

D8H :-40

 

 

:

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

:

 

 

1EH: +30

 

DATA03: BLUE Gain2 (Drive)

D8H:-40

 

 

:

 

 

FFH: -01

 

 

00H: 0

 

 

01H: +01

 

 

:

 

 

1EH: +30

ACK

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

01H

 

DATA01: BLUE Gain Flag

03H

Company Restricted

Page 14
Image 14
Marantz PDxx01 specifications Green Gain Data, Blue Gain Data