5-13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00: 00H: low 01H: middle
02H: high
03H: middle low
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00: 00H: low 01H: middle
02H: high
03H: middle low
5-14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag | 01H |
|
DATA01: RED Gain Flag | 01H |
|
DATA02: RED Gain 1(Bias) | D8H : | |
| : |
|
| FFH : | |
| 00H | : 0 |
| 01H | : +01 |
| : |
|
| 1EH : +30 | |
DATA03: RED Gain 2(Drive) | D8H : | |
| : |
|
| FFH : | |
| 00H | : 0 |
| 01H | : +01 |
| : |
|
| 1EH : +30 | |
ACK |
|
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: RED Gain Flag | 01H |