PDxx01

RS-232C Control Specification

Page: 43 / 49

Document Version [1.0]

5-66.PICTURE MEMORY Set

Function

The external control equipment ser and reset the Picture Memory function of a plasma monitor.

Transmission Data

DFH 80H 60H 25H 02H DATA00 DATA01 CKS

DATA00:

01H: SET

 

02H: RESET

DATA01: MEMORY select

00H: OFF

 

01H: MEMORY1

 

02H: MEMORY2

 

03H: MEMORY3

 

04H: MEMORY4

 

05H: MEMORY5

 

06H: MEMORY6

ACK

The plasma monitor returns the following ACK when the input is switched. 7FH 60H 80H 25H 01H CKS

DATA00:

01H: SET

 

02H: RESET

NOTE: When “PICTURE MEMORY” selects “OFF”, this command is no support.

5-67.PICTURE MEMORY NOTE WRITE Set

Function

External control apparatus writes to NOTE of PICTURE MEMORY of a plasma display.

Transmission Data

 

 

 

 

DFH 80H 60H 2DH 0FH

DATA00 to DATA14 CKS

 

Even DATA00-DATA14 is set up as follows.

 

Setting value

00H-09H :

0 - 9

 

 

80H

: - (Hyphen)

 

 

81H

: +

 

 

82H

:

 

 

 

83H

: /

 

 

84H

: (

 

 

85H

: )

 

 

86H

: .

 

 

87H

: ‘

 

 

96H

: Blank

 

 

10H-29H:

A-Z of Alphabet

Company Restricted

Page 43
Image 43
Marantz PDxx01 specifications Picture Memory Set, Picture Memory Note Write Set, DFH 80H 60H 25H 02H DATA00 DATA01 CKS