5-66. PICTURE MEMORY Set
Function
The external control equipment ser and reset the Picture Memory function of a plasma monitor.
Transmission Data
DFH 80H 60H 25H 02H DATA00 DATA01 CKS
DATA00: | 01H: SET |
| 02H: RESET |
DATA01: MEMORY select | 00H: OFF |
| 01H: MEMORY1 |
| 02H: MEMORY2 |
| 03H: MEMORY3 |
| 04H: MEMORY4 |
| 05H: MEMORY5 |
| 06H: MEMORY6 |
ACK
The plasma monitor returns the following ACK when the input is switched. 7FH 60H 80H 25H 01H CKS
DATA00: | 01H: SET |
| 02H: RESET |
NOTE: When “PICTURE MEMORY” selects “OFF”, this command is no support.
5-67. PICTURE MEMORY NOTE WRITE Set
Function
External control apparatus writes to NOTE of PICTURE MEMORY of a plasma display.
Transmission Data |
|
|
| |
| DFH 80H 60H 2DH 0FH | DATA00 to DATA14 CKS | ||
| Even | |||
| Setting value | 0 - 9 | ||
|
| 80H | : - (Hyphen) | |
|
| 81H | : + | |
|
| 82H | : |
|
|
| 83H | : / | |
|
| 84H | : ( | |
|
| 85H | : ) | |
|
| 86H | : . | |
|
| 87H | : ‘ | |
|
| 96H | : Blank | |
|
|