5-11.TINT Gain Data

Function

The external control equipment changes the TINT gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: TINT Gain Flag

05H

DATA02: TINT Gain

E0H: -32

 

:

* TINT Gain is from -22 (EAH) to

FFH: -01

+22 (16H) only during video.

00H: 0

 

01H: +01

 

:

 

20H: +32

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: TINT Gain Flag

05H

5-12.PICTURE MODE Select

Function

The external control equipment sets the picture mode of the plasma monitor.

Transmission Data

DFH 80H 60H 0AH 01H DATA00 CKS

DATA00: 01H: NORMAL

02H: THEATER1 (It cannot choose in the still picture input of a personal computer.)

03H: THEATER2 (It cannot choose in the still picture input of a personal computer.)

04H: Default

05H: Bright

ACK

7FH 60H 80H 0AH 01H DATA00 CKS

DATA00: 01H: NORMAL 02H: THEATER1

03H: THEATER2

04H: Default

05H: Bright